Autelis manufactures a network enabled pool interface for many popular pool systems. See the Autelis website and the Autelis Command Protocol for more information.
This binding supports:
- Jandy and Pentair models
- Read circuit, auxiliary, temperature, pump, chemistry and system values
- Control circuit, auxiliary lighting scenes, and temperature set points
The binding will automatically discover Autelis controllers using UPNP. If found it will try and connect with the factory default username and password.
The binding requires no special configuration
The Autelis binding requires the host, port, username and password
In the thing file, this looks e.g. like
Thing autelis:pentair:myPool [ host="192.168.1.10", port="80", user="admin", password="admin"]
or
Thing autelis:jandy:myPool [ host="192.168.1.10", port="80", user="admin", password="admin"]
Pentair devices support the following channels:
Channel Type ID | Item Type |
---|---|
system-runstate | Number |
system-model | Number |
system-haddr | Number |
system-opmode | Number |
system-freeze | Number |
system-sensor1 | Number |
system-sensor2 | Number |
system-sensor3 | Number |
system-sensor4 | Number |
system-sensor5 | Number |
system-version | String |
system-time | Number |
equipment-circuit1 | Switch |
equipment-circuit2 | Switch |
equipment-circuit3 | Switch |
equipment-circuit4 | Switch |
equipment-circuit5 | Switch |
equipment-circuit6 | Switch |
equipment-circuit7 | Switch |
equipment-circuit8 | Switch |
equipment-circuit9 | Switch |
equipment-circuit10 | Switch |
equipment-feature1 | Number |
equipment-feature2 | Number |
equipment-feature3 | Number |
equipment-feature4 | Number |
equipment-feature5 | Number |
equipment-feature6 | Number |
equipment-feature7 | Number |
equipment-feature8 | Number |
equipment-feature9 | Number |
equipment-feature10 | Number |
temp-poolht | Number |
temp-spaht | Number |
temp-htstatus | Number |
temp-poolsp | Number |
temp-spasp | Number |
temp-pooltemp | Number |
temp-spatemp | Number |
temp-airtemp | Number |
temp-tempunits | String |
temp-htpump | Number |
pump-pump1 | String |
pump-pump2 | String |
pump-pump3 | String |
pump-pump4 | String |
pump-pump5 | String |
pump-pump6 | String |
pump-pump7 | String |
pump-pump8 | String |
chlor-chloren | Number |
chlor-poolsp | Number |
chlor-spasp | Number |
chlor-salt | Number |
chlor-super | Number |
chlor-chlorerr | Number |
chlor-chlorname | String |
lightscmd | String |
reboot | Switch |
Jandy devices support the following channels:
Channel Type ID | Item Type |
---|---|
system-model | Number |
system-dip | Number |
system-opmode | Number |
system-vbat | Number |
system-lowbat | Number |
system-time | Number |
equipment-pump | Number |
equipment-pumplo | Number |
equipment-spa | Number |
equipment-waterfall | Number |
equipment-cleaner | Number |
equipment-poolht | Number |
equipment-poolht2 | Number |
equipment-spaht | Number |
equipment-solarht | Number |
equipment-htpmp | Number |
equipment-aux1 | Number |
equipment-aux2 | Number |
equipment-aux3 | Number |
equipment-aux4 | Number |
equipment-aux5 | Number |
equipment-aux6 | Number |
equipment-aux7 | Number |
equipment-aux8 | Number |
equipment-aux9 | Number |
equipment-aux10 | Number |
equipment-aux11 | Number |
equipment-aux12 | Number |
equipment-aux13 | Number |
equipment-aux14 | Number |
equipment-aux15 | Number |
temp-poolsp | Number |
temp-poolsp2 | Number |
temp-pooltemp | Number |
temp-spatemp | Number |
temp-airtemp | Number |
temp-solartemp | Number |
temp-tempunits | String |
pump-vsp1 | String |
pump-vsp2 | String |
pump-vsp3 | String |
pump-vsp4 | String |
chem-avail | Number |
chem-chlrp | Number |
chem-saltp | Number |
chem-chlrs | Number |
chem-slats | Number |
chem-orp1 | Number |
chem-orp2 | Number |
chem-ph1 | Number |
chem-ph2 | Number |
chem-orpfd1 | Number |
chem-orpfd2 | Number |
chem-phfd1 | Number |
chem-phfd2 | Number |
reboot | Switch |