forked from evcc-io/evcc
-
Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathevcc.dist.yaml
153 lines (143 loc) Β· 4.05 KB
/
evcc.dist.yaml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
uri: 0.0.0.0:7070 # uri for ui
interval: 10s # control cycle interval
# log settings
log: error
levels:
core: debug
lp-1: debug
lp-2: debug
# mqtt message broker
mqtt:
broker: localhost:1883
topic: evcc # root topic for publishing, set empty to disable
# user:
# password:
# influx database
influx:
url: http://localhost:8086
database: evcc
# user:
# password:
# additional menu entries
menu:
# - title: "Verlauf"
# subtitle: "Bezugs- und Einspeiseleistung"
# img: "http://..."
# link: "http://..."
# iframe: "http://..."
# push messages
messaging:
events:
start: # charge start event
title: Charge started
msg: Started charging in "${mode}" mode
stop: # charge stop event
title: Charge finished
msg: Finished charging ${chargedEnergy:%.1fk}kWh in ${chargeDuration}.
connect: # vehicle connect event
title: Car connected
msg: "Car connected at ${pvPower:%.1fk}kW PV"
disconnect: # vehicle connected event
title: Car disconnected
msg: Car disconnected after ${connectedDuration}
services:
# - type: pushover
# app: # app id
# recipients:
# - # list of recipient ids
# - type: telegram
# token: # bot id
# chats:
# - # list of chat ids
# - type: email
# uri: smtp://<user>:<password>@<host>:<port>/?fromAddress=<from>&toAddresses=<to>
# meter definitions
# name can be freely chosen and is used as reference when assigning meters to site and loadpoints
meters:
- name: grid
type: modbus
model: sdm # SDM630
uri: rs485.fritz.box:23
rtu: true # rs485 device connected using ethernet adapter
id: 2
power: Power # default value, optionally override
energy: Sum # default value, optionally override
- name: pv
type: ... # examples see https://github.com/andig/evcc-config#meters
- name: battery
type: ...
- name: charge
# charger definitions
# name can be freely chosen and is used as reference when assigning charger to vehicle
chargers:
- name: wallbe
type: wallbe # Wallbe charger
uri: 192.168.0.8:502 # ModBus address
- name: keba
type: ... # https://github.com/andig/evcc-config#chargers
# vehicle definitions
# name can be freely chosen and is used as reference when assigning vehicle to loadpoint
vehicles:
- name: renault
type: renault
title: Zoe
capacity: 60 # kWh
user: # user
password: # password
region: de_DE # gigya region
vin: WREN...
cache: 5m
- name: default
type: default
title: Default
capacity: 50 # kWh
charge:
type: script # use script
cmd: /bin/sh -c "echo 50" # actual command
timeout: 3s # kill script after 3 seconds
cache: 5m
- name: bmw
type: bmw
title: i3
capacity: 65 # kWh
user: # user
password: # password
vin: WBMW...
cache: 5m
# site describes the EVU connection, PV and home battery
site:
title: Home # display name for UI
meters:
grid: grid # grid meter
pv: pv # pv meter
battery: battery # battery meter
# loadpoint describes the charger, charge meter and connected vehicle
loadpoints:
- title: Garage # display name for UI
charger: wallbe # charger
meters:
charge: charge # charge meter
vehicle: audi
mode: pv
targetSoC: 100 # charge to 100%
soc:
alwaysUpdate: false # set true to update vehicle soc even when disconnected
levels: # target soc levels for UI
- 30
- 50
- 80
- 100
onDisconnect: # set defaults when vehicle disconnects
mode: pv # switch back to pv mode
targetSoC: 100 # charge to 100%
phases: 3 # ev phases (default 3)
sensitivity: 1 # current raise/lower step size (default 10A)
enable: # pv mode enable behavior
delay: 1m # threshold must be exceeded for this long
threshold: 0 # minimum export power (W). If zero, export must exceed minimum charge power to enable
disable: # pv mode disable behavior
delay: 5m # threshold must be exceeded for this long
threshold: 200 # maximum import power (W)
guardduration: 10m # switch charger contactor not more often than this (default 10m)
mincurrent: 6 # minimum charge current (default 6A)