 DESCRIPTION
==============================================================================

Network UPS Tools is a collection of programs which provide a common
interface for monitoring and administering UPS hardware.  It uses a
layered approach to connect all of the parts.

Drivers are provided for a wide assortment of equipment.  They
understand the specific language of each UPS and map it back to a
compatibility layer.  This means both an expensive "smart" protocol UPS
and a simple "power strip" model can be handled transparently.

This information is cached by the network server upsd, which then
answers queries from the clients.  upsd contains a number of access
control features to limit the abilities of the clients.  Only authorized
hosts may monitor or control your UPS hardware if you wish.  Since the
notion of monitoring over the network is built into the software, you
can hang many systems off one large UPS and they will all shut down
together.

Clients such as upsmon check on the status of the hardware and do things
when necessary.  The most important task is shutting down the operating
system cleanly before the UPS runs out of power.  Other programs are
also provided to log UPS status regularly, monitor status through your
web browser, and more.


==============================================================================
 INSTALLING
==============================================================================

If you are installing these programs for the first time, go read the
INSTALL file to find out how to do that.  This document contains more
information on what all of this stuff does.


==============================================================================
 UPGRADING
==============================================================================

When upgrading from an older version, always check the UPGRADING file to
see what may have changed.  Compatibility issues and other changes will
be listed there to ease the process.


==============================================================================
 DOCUMENTATION
==============================================================================

This file gives an overview of the software.  You should read the man
pages, included example configuration files, and auxiliary documentation
for the parts that you intend to use.


=============================================================================
 NETWORK INFORMATION
==============================================================================

These programs are designed to share information over the network.  In
the examples below, "localhost" is used as the hostname.  This can also
be an IP address or a fully qualified domain name.  You can specify a
port number if your upsd process runs on another port.

In the case of the program upsc, to view the variables on the ups called
sparky on the upsd server running on the local machine, you'd do this:

	/usr/local/ups/bin/upsc sparky@localhost

The default port number is 3493.  You can change this with 
"configure --with-port" at compile-time.  To make a client talk to upsd
on a specific port, add it after the hostname with a colon, like this:

	/usr/local/ups/bin/upsc sparky@localhost:1234

This is handy when you have a mixed environment and some of the systems
are on different ports.

The general form for UPS identifiers is this:

	<upsname>@<hostname>[:<port>]

Keep this in mind when viewing the examples below.


==============================================================================
 MANIFEST
==============================================================================

This package is broken down into several categories:

 - drivers - These programs talk directly to your UPS hardware. 

 - server  - upsd serves data from the drivers to the network.

 - clients - They talk to upsd and do things with the status data.

 - cgi-bin - Special class of clients that you can use with your web server.


==============================================================================
 DRIVERS
==============================================================================

These programs provide support for specific UPS models.  They understand
the protocols and port specifications which define status information
and convert it to a form that upsd can understand.

To configure drivers, edit ups.conf.  For this example, we'll have a UPS
called "sparky" that uses the apcsmart driver and is connected to
/dev/ttyS1.  That's the second serial port on most Linux-based systems.
The entry in ups.conf looks like this:

	[sparky]
		driver = apcsmart
		port = /dev/ttyS1

To start and stop drivers, use upsdrvctl.  By default, it will start or
stop every UPS in the config file:

	/usr/local/ups/bin/upsdrvctl start
	/usr/local/ups/bin/upsdrvctl stop

However, you can also just start or stop one by adding its name:

	/usr/local/ups/bin/upsdrvctl start sparky
	/usr/local/ups/bin/upsdrvctl stop sparky

 EXTRA SETTINGS
 --------------

Some drivers may require additional settings to properly communicate
with your hardware.  If it doesn't detect your UPS by default, check the
driver's man page or help (-h) to see which options are available.

For example, the apcsmart driver allows setting "cable" to "940-0095B".
To use this feature, just add another line to your ups.conf section for
that UPS.

	[sparky]
		driver = apcsmart
		port = /dev/ttyS1
		cable = 940-0095B

 HARDWARE SUPPORT TABLE
 ----------------------

	al175            - Eltek models with AL175 alarm module

	apcsmart         - APC Smart-UPS, Back-UPS Pro, Matrix-UPS models

	bcmxcp           - some Powerware models

	bcmxcp_usb       - some Powerware USB models

	belkin           - Belkin Regulator Pro

	belkinunv	 - Belkin Universal UPS (F6C800-UNV, others)

	bestuferrups	 - Best Power Micro-Ferrups models

	bestups          - Best Power models: (newer, usually beige)

                           - Fortress (FOR)
                           - Fortress Telecom (FTC)
                           - Patriot Pro (PRO)
                           - Patriot Pro II (PR2)
                           - Axxium Rackmount (AX1)

                           The SOLA 325, 520 and 620 are also recognized. 

                           This driver will probably also work with other
                           PhoenixTec protocol hardware.

                           The SOLA 610 will work with the ID= variable
                           in ups.conf.

	cyberpower       - Cyber Power Systems units
			   700AVR and others (binary protocol)

	cpsups           - Cyber Power Systems units (experimental)
			   CPS825VA, 1100AVR, 1500AVR-HO, OP500TE, others
			   (text protocol) 

	energizerups	 - Energizer UPS hardware (experimental - USB/Linux)

	etapro		 - ETA UPS hardware with the "PRO" smart mode

	everups          - EVER Sp. z o.o models

                           - NET *-DPC
                           - AP *-PRO 

	genericups       - Many contact closure models -
                           see "Generic UPS driver" below 

	isbmex		 - SOLA/BASIC Mexico ISBMEX protocol hardware

	liebert          - Liebert UPStation GXT2 with contact-closure cable

	masterguard	 - Masterguard UPS hardware

	metasys  	 - Meta System ups models:

                           - HF Line (/2) 1-8 boards
                           - HF Millennium (810, 820)
                           - HF TOP Line (910, 920, 930, 940, 950, 970, 980)
                           - ECO Network (750, 1000, 1050, 1500,
                             1800, 2000, 2100, 2500, 3000)
                           - ECO (305, 308, 311, 511, 516, 519,
                             522, SX, SXI)
                           - ally HF (800, 1000, 1250, 1600, 2000, 2500)
                           - Megaline (1250, 2500, 3750, 5000,
                             6250, 7500, 8750, 10000)

	mge-shut	 - MGE UPS SYSTEMS serial SHUT units:

                           - Pulsar Ellipse / Ellipse Premium S,
                           - Pulsar Ellipse / Ellipse Premium USBS,
                           - NOVA AVR Serial
                           - Pulsar Evolution,
                           - Pulsar EXtreme C,
                           - Pulsar EXtreme C / EX RT,
                           - Pulsar Esprit,
                           - Pulsar / Comet EXtreme,
                           - Comet / Galaxy using HID COM Serial Card (ref 66066)

	mge-utalk	 - MGE UPS SYSTEMS serial UTalk units:

                           - Pulsar Evolution,
                           - Pulsar EX / EXL / PSX / SX
                           - Pulsar ES+ / SV / ESV / ESV+,
                           - Pulsar EXtreme C,
                           - Pulsar / Comet EXtreme,
                           - Comet / Galaxy using Utalk Serial Card (ref 66060)

	megatec		 - Megatec protocol based UPSes (Mustek Powermust,
			   OnLite 50, Maxxtro units, etc.)


	usbhid-ups - Meta driver for USB HID UPSes on various platforms
                           (replaces hidups, formerly named newhidups)

                           Some units that have been used with this driver:

                           - All MGE UPS SYSTEMS USB models,
                           - various APC units,
                           - Belkin F6C800-UNV, F6C550-AVR

                           NOTE: not built by default.  Read the FAQ
                           to find out how to build/install/use this one.
 
	nitram		 - Nitram Elite 2005 units

	oneac		 - Oneac EG and ON equipment

	powercom	 - Trust 425/625
			 - Powercom units
			 - Advice Partner/King PR750
                         - Socomec Sicon Egys 420 VA 

	safenet		 - Units typically bundled with Safenet software:

                           - Ever-Power UF 010C2EJA
                           - Fairstone L525/-625/-750
                           - Fenton P400/-600/-800
                           - Gemini UPS625/-1000
                           - Powerwell PM525A/-625A/-800A/-1000A/-1250A
                           - Repotec RPF525/-625/-800/-1000
                           - Soltec Winmate 525/625/800/1000
                           - Sweex 500/1000 (if shipped with Safenet)

                           Note: Sweex models which shipped with UPSmart
                           are contact-closure and need to use the
                           genericups driver with upstype=7.

	snmp-ups         - SNMP UPS equipment
                           Experimental driver - not built by default.

                           MIBs supported:
                           - various RFC 1628 compliant devices,
                           - MGE UPS SYSTEMS MIB,
                           - APC Powernet MIB,
                           - Powerware MIB,
                           - Socomec Netvision MIB.

                           See docs/drivers/snmp-ups.txt for more
                           information.

	tripplite	 - Tripp-Lite SmartUPS units

	tripplitesu	 - Tripp-Lite SmartOnline units

        upscode2         - Fiskars, Compaq and Powerware units

	victronups	 - IMV/Victron hardware

For another take on this list, try the web page: 

	http://random.networkupstools.org/compat/

If your driver has vanished, see the FAQ.

 GENERIC UPS DRIVER
 ------------------

The "genericups" driver will support many models that use the same basic
principle to communicate with the computer.  This is known as "contact
closure", and basically involves raising or lowering signals to indicate
power status.

This type of UPS tends to be cheaper, and only provides the very simplest
data about power and battery status.  Advanced features like battery
charge readings and such require a "smart" UPS and a driver which
supports it.

See the genericups(8) man page for more information.

There is also a document called contact-closure.txt included with the
source distribution that contains information on this kind of hardware
and details on adding additional types to the genericups driver.

 UPS SHUTDOWNS
 -------------

upsdrvctl can also shut down (power down) all of your UPS hardware.

WARNING - if you play around with this command, expect your filesystems
to die.  Don't power off your computers unless they're ready for it.

	/usr/local/ups/bin/upsdrvctl shutdown
	/usr/local/ups/bin/upsdrvctl shutdown sparky

You should read the shutdown.txt file in the docs subdirectory to
learn more about when to use this feature.  If called at the wrong time,
you may cause data loss by turning off a system with a filesystem
mounted read-write.


==============================================================================
 NETWORK SERVER
==============================================================================

upsd is responsible for passing data from the drivers to the client 
programs via the network.  It should be run immediately after upsdrvctl
in your system's startup scripts.

upsd should be kept running whenever possible, as it is the only source
of status information for the monitoring clients like upsmon.


==============================================================================
 UPSMON
==============================================================================

upsmon provides the essential feature that you expect to find in UPS
monitoring software: safe shutdowns when the power fails.

In the layered scheme of NUT software, it is a client.  It has this
separate section in the documentation since it is so important.

You configure it by telling it about UPSes that you want to monitor in
upsmon.conf.  Each UPS can be defined as one of three possible types:

 - Master

	This UPS supplies power to the system running upsmon, and
	this system is also responsible for shutting it down when
	the battery is depleted.  This occurs after any slave systems
	have disconnected safely.

	If your UPS is plugged directly into a system's serial port,
	the upsmon on that system should define that UPS as a master.

 - Slave

	This UPS supplies power to the system running upsmon, but 
	this system can't shut it down directly.  This system will
	shut down the operating system before the master turns off the
	power.

	Use this mode when you run multiple computers on the same UPS.
	Obviously, only one can be connected to the serial port on the
	UPS, and that system is the master.  Everything else is a
	slave.
   
 - Monitor-only

	This UPS will still generate notifications about status
	changes (on battery, on line, etc.) but no shutdowns of the
	local system result from critical situations on that UPS.

For a typical home user, there's one computer connected to one UPS.
That means you run a driver, upsd, and upsmon in master mode.

 ADDITIONAL INFORMATION
 ----------------------

More information on configuring upsmon can be found in these places:

 - The man page - upsmon(8)

 - big-servers.txt in the docs subdirectory

 - shutdown.txt in the docs subdirectory

 - The stock upsmon.conf that comes with the package


==============================================================================
 CLIENTS
==============================================================================

Clients talk to upsd over the network and do useful things with the data
from the drivers.  There are tools for command line access, and a few
special clients which can be run through your web server as CGI
programs.

For more details on specific programs, refer to their man pages.

 UPSC
 ----

upsc is a simple client that will display the values of variables known
to upsd and your UPS drivers.  It will list every variable by default,
or just one if you specify an additional argument.  This can be useful 
in shell scripts for monitoring something without writing your own 
network code.

upsc is a quick way to find out if your driver(s) and upsd are working
together properly.  Just run upsc <ups> to see what's going on, i.e.:

	morbo:~$ upsc su700@localhost
	ambient.humidity: 035.6
	ambient.humidity.alarm.maximum: NO,NO
	ambient.humidity.alarm.minimum: NO,NO
	ambient.temperature: 25.14

	[ and so on ]

If you are interested in writing a simple client that monitors upsd,
the source code for upsc is a good way to learn about using the 
upsclient functions.

See the upsc(8) man page for more information.

 UPSLOG
 ------

upslog will write status information from upsd to a file at set
intervals.  You can use this to generate graphs or reports with other
programs such as gnuplot.

 UPSRW
 -----

upsrw allows you to display and change the read/write variables in your
UPS hardware.  Not all devices or drivers implement this, so this may
not have any effect on your system.  

A driver that supports read/write variables will give results like this:

	$ upsrw su700@localhost

	( many skipped )

	[ups.test.interval]
	Interval between self tests
	Type: ENUM
	Option: "1209600"
	Option: "604800" SELECTED
	Option: "0"

	( more skipped )

On the other hand, one that doesn't support them won't print anything:

	$ upsrw fenton@gearbox

	( nothing )

upsrw requires administrator powers to change settings in the hardware.
Refer to upsd.users(5) for information on defining users in upsd.

 UPSCMD
 ------

Some UPS hardware and drivers support the notion of an instant command -
a feature such as starting a battery test, or powering off the load.
You can use upscmd to list or invoke instant commands if your
hardware/drivers support them.

Use the -l command to list them, like this:

	$ upscmd -l su700@localhost
	Instant commands supported on UPS [su700@localhost]:

	load.on - Turn on the load immediately
	test.panel.start - Start testing the UPS panel
	calibrate.start - Start run time calibration
	calibrate.stop - Stop run time calibration

	[ snip ]

upscmd requires administrator powers to start instant commands.
To define users and passwords in upsd, see upsd.users(5).


==============================================================================
 CGI PROGRAMS
==============================================================================

The CGI programs are clients that run through your web server.  They
allow you to see UPS status and perform certain administrative commands
from any web browser.  Javascript and cookies are not required.

These programs are not installed or compiled by default.  To compile
and install them, first run 'configure --with-cgi', then do 'make' and
'make install'.  If you receive errors about "gd" during configure, go
get it and install it before continuing.

You can get the source here:

	http://www.boutell.com/gd/

In the event that you need libpng or zlib in order to compile gd, 
they can be found at these URLs:

	http://www.libpng.org/pub/png/pngcode.html

	http://www.gzip.org/zlib/

 ACCESS RESTRICTIONS
 ===================

The CGI programs use hosts.conf to see if they are allowed to talk to a
host.  This keeps malicious visitors from creating queries from your web
server to random hosts on the Internet.

If you get error messages that say "Access to that host is not
authorized", you're probably missing an entry in your hosts.conf.

 UPSSTATS
 ========

upsstats generates web pages from HTML templates, and plugs in status
information in the right places.  It looks like a distant relative of
APC's old Powerchute interface.  You can use it to monitor several
systems or just focus on one.

It also can generate IMG references to upsimage.

 UPSIMAGE
 ========

This is usually called by upsstats via IMG SRC tags to draw either the
utility or outgoing voltage, battery charge percent, or load percent.

 UPSSET
 ======

upsset provides several useful administration functions through a web
interface.  You can use upsset to kick off instant commands on your UPS
hardware like running a battery test.  You can also use it to change
variables in your UPS that accept user-specified values.

Essentially, upsset provides the functions of upsrw and upscmd, but
with a happy pointy-clicky interface.

upsset will not run until you convince it that you have secured your
system.  You *must* secure your CGI path so that random interlopers
can't run this program remotely.  See the upsset.conf file.  Once you
have secured the directory, you can enable this program in that
configuration file.  It is not active by default.


==============================================================================
 SUPPORT / HELP / ETC.
==============================================================================

The main URL:

	http://www.networkupstools.org/

There is also a mailing list for general queries and discussion about
this software called nut-upsuser.  It typically moves around 50-100 messages
per month at the time of this writing.  To join, go to the below address and
subscribe to the desired list.

Finally, there is a developer list called nut-upsdev.  This is not
an install help list, and any such mails probably will be ignored.

The mailing lists are archived on the web:

	http://alioth.debian.org/mail/?group_id=30602

Try running some searches against the archives.  Many times, problems have
already been answered by someone else. Currently, there is no internal
search engine, so you will have to try with a search engine like Google.

There is more documentation in the docs/ directory within the source 
tree.  Be sure to read through the files in there (especially the
FAQ) before mailing the list for help.  Many times the questions have
already been answered in the files which are right in front of you.


==============================================================================
 MAKING YOUR OWN CLIENTS (UPSCLIENT)
==============================================================================

The upsclient.a library can be linked into other programs to give access
to upsd and UPS status information.  Clients like upsc are provided as
examples of how to retrieve data using the upsclient functions.  Other
programs not included in this package may also use this library, as wmnut.

This library file and the associated header files are not installed by
default.  You must './configure --with-lib' to enable building and
installing these files. The libraries can then be build and installed
with 'make' and 'make install' as usual. This must be done before
building other (non-NUT) programs which depend on them.

To obtain the right compilation and link flags, two helpers are provided:
one for platform providing pkg-config, and the other (libupsclient-config)
for platform not providing pkg-config.


==============================================================================
 VERSION NUMBERING
==============================================================================

The version numbers work like this: if the middle number is odd, it's a
development tree, otherwise it is the stable tree.

The past stable trees were 1.0, 1.2 and 1.4, with the latest stable tree
designated 2.0.  The development trees were 1.1, 1.3 and 1.5.

The jump to 2.0 is mostly due to the large changes to the network
protocol.  There have also been a number of architectural changes which
may not be noticeable to most users.


==============================================================================
 BACKWARDS AND FORWARDS COMPATIBILITY
==============================================================================

The old network code spans a range from about 0.41.1 when TCP support 
was introduced up to the recent 1.4 series.  It used variable names
like STATUS, UTILITY, and LOADPCT.  Many of these names go back to the
earliest prototypes of this software from 1997.  At that point there
was no way to know that so many drivers would come along and introduce 
so many new variables and commands.  The resulting mess grew out of
control over the years.

During the 1.3 development cycle, all variables and instant commands
were renamed to fit into a tree-like structure.  There are major groups,
like input, output and battery.  Members of those groups have been
arranged to make sense - input.voltage and output.voltage compliment
each other.  The old names were UTILITY and OUTVOLT.  The benefits in
this change are obvious.

The 1.4 clients can talk to either type of server, and can handle either
naming scheme.  1.4 servers have a compatibility mode where they can
answer queries for both names, even though the drivers are internally
using the new format.

When 1.4 clients talk to 1.4 or 2.0 servers, they will use the new
names.

Here's a table to make it easier to visualize:

   +--------------------------------+
   |        |        Server         |
   |--------+-----------------------|
   | Client | 1.0 | 1.2 | 1.4 | 2.0 |
   |--------+-----+-----+-----+-----|
   | 1.0    | yes | yes | yes | no  |
   |--------+-----+-----+-----+-----|
   | 1.2    | yes | yes | yes | no  |
   |--------+-----+-----+-----+-----|
   | 1.4    | yes | yes | yes | yes |
   |--------+-----+-----+-----+-----|
   | 2.0    | no  | no  | yes | yes |
   +--------------------------------+

Version 2.0 does not contain backwards compatibility for the old 
protocol and variable/command names.  As a result, 2.0 clients can't 
talk to anything older than a 1.4 server.  If you ask a 2.0 client to 
fetch "STATUS", it will fail.  You'll have to ask for "ups.status" 
instead.

Authors of separate monitoring programs should have used the 1.4 series
to write support for the new variables and command names.  Client
software can easily support both versions as long as they like.  If upsd
returns 'ERR UNKNOWN-COMMAND' to a GET request, you need to use REQ.


==============================================================================
 HACKING / DEVELOPMENT INFO
==============================================================================

Additional documentation can be found in the docs subdirectory.

Information on creating new drivers can be found in new-drivers.txt.
Also be sure to look at skel.c and main.c.  All drivers are just
collections of support functions built around a common core, so most of
the dull housekeeping work has been handled for you.

Information on the architecture and how it all fits together is in the
design.txt file.  In short, there's a lot more documentation out there.

Also be sure to read developers.txt, as it explains a lot about the
tree, including some of the functions that are provided for your use.


==============================================================================
 ACKNOWLEDGEMENTS / CONTRIBUTIONS
==============================================================================

MGE UPS SYSTEMS provided extensive technical documents for their UPS product
line, along with many units for development of NUT-related projects. The
company also sponsored and later hired Arnaud Quette to further officially
support these efforts. 
Several drivers such as mge-utalk, mge-shut, snmp-ups, hidups, and usbhid-ups
are the result of this collaboration, in addition to the WMNut, MGE HID Parser
the libhid projects, .... The features page has improved artwork thanks to Luc
and Arnaud of MGE. Other client projects such as KNutClient and ups-monitor
have also received assistance. 
The master NUT site and several related projects are hosted on MGE's equipment
at no cost to the project.
More information on their open source support can be found on their web site:
http://opensource.mgeups.com/contrib.htm 

Fenton Technologies contributed a PowerPal 660 to the project.  Their open 
stance and quick responses to technical inquiries are appreciated for 
making the development of the fentonups driver possible.

Bo Kersey of VirCIO (http://www.vircio.com) provided a Best Power 
Fortress 750 to facilitate the bestups driver.  

Invensys Energy Systems provided the SOLA/Best "Phoenixtec" protocol
document currently residing at the following URL:

	http://random.networkupstools.org/protocols/sola.html

PowerKinetics technical support provided documentation on their MiniCOL
protocol, which is archived in the NUT protocol library online:

	http://random.networkupstools.org/protocols/minicol/

Cyber Power Systems contributed a 700AVR model for testing and driver
development.

Liebert Corporation supplied serial test boxes and a UPStation GXT2  
with the Web/SNMP card for development of the liebert driver and
expansion of the existing snmp-ups driver.

All donated equipment can usually be seen on the big status page:

	http://www.exploits.org/cgi-bin/ups/upsstats.cgi

About

The Network UPS Tools repository

Resources

License

Unknown and 2 other licenses found

Licenses found

Unknown
COPYING
GPL-2.0
LICENSE-GPL2
GPL-3.0
LICENSE-GPL3

Security policy

Stars

Watchers

Forks

Packages

No packages published

Languages

  • C 86.4%
  • Shell 3.9%
  • M4 3.8%
  • C++ 2.2%
  • Python 1.7%
  • Makefile 1.0%
  • Other 1.0%