forked from Checkmk/checkmk
-
Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathadva_fsp_temp
27 lines (22 loc) · 1.01 KB
/
adva_fsp_temp
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
title: Adva FSP 3000 Optical Transport: Temperature
catalog: hw/network/adva
agents: snmp
license: GPL
distribution: check_mk
description:
This checks monitors the temperature of ports and modules of the Adva
FSP 3000 scalable optical transport solution.
No limits are set for the temperature, since limits are configured in the
device itself. The upper and lower limits for the temperature are
read from the device. If the current value is outside the allowed
range the check is {CRIT}, otherwise it is {OK}.
In addition {temperature trends} are monitored by the check. If the rate of
temperature increase is above a configured rate per configured time range,
the check becomes {WARN} or {CRIT}. The check can also predict in which
period of time the upper limit for the temperature configured on the device
will be reached and will become {WARN} or {CRIT} if this time period is
shorter than the configured one.
item:
The name of the module or port
inventory:
All temperature sensors on all modules/ports are detected