Areas of application: heating / solar / domestic ventilation

The adapter can evaluate a maximum of 4 of the following heaters via the ISM8i:

  • Gas condensing unit: CGB-2 (includes: CGW-2, CGS-2, CSZ-2), MGK-2
  • Oil condensing boiler: TOB
  • Split heat pump: BWL-1-S
  • Living room ventilation CWL Excellent A system control module BM-2 or display module AM is always required. Furthermore, additional components such as mixer module MM, cascade module KM, solar module SM1 or SM2, may be present in the eBus system.

Maximum number of individual modules:

  • Max. 4 heaters hg (1) -hg (4)
  • Max. 3 mixers mm (1) - mm (3)
  • Max. 4 operator panels (BM-2) bm (1) -bm (4)
  • Max. 1 cascade module km (1)
  • Max. 1 solar module (SM1 or SM2) sm (1)
  • Max. 1 Split air/water heatpump (BWL-1-S) hg (0) A residential ventilation unit of the CWL Excellent series can also be evaluated and operated with the ISM8i.

Einsatzbereiche: Heizung / Solar / Wohnraumlüftung

Der Adapter kann über das ISM8i maximal 4 von den nachfolgenden Heizgeräten auswerten:

  • Gasbrennwertgerät: CGB-2 (beinhaltet: CGW-2, CGS-2, CSZ-2), MGK-2
  • Öl Brennwertkessel: TOB
  • Split-Wärmepumpe: BWL-1-S
  • Wohnraumlüftung CWL Excellent Es ist immer ein System-Bedienmodul BM-2 oder Anzeigemodul AM erforderlich. Weiterhin können zusätzliche Komponenten wie Mischermodul MM, Kaskadenmodul KM, Solarmodul SM1 oder SM2, im eBusSystem vorhanden sein.

Maximale Anzahl der einzelnen Module:

  • max. 4 Heizgeräte hg(1)-hg(4)
  • max. 3 Mischer mm(1)- mm(3)
  • max. 4 Bediengeräte (BM-2) bm(1) -bm(4)
  • max. 1 Kaskadenmodul km(1)
  • max. 1 Solarmodul (SM1 oder SM2) sm(1)
  • max. 1 Split-Luft/Wasser-Wärmepumpe (BWL-1-S) hg(0) Ein Wohnraumlüftungsgerät der Baureihe CWL Excellent kann mit dem ISM8i ebenfalls ausgewertet und bedient werden.

Changelog

1.1.0 [2019.09.13]

  • (RustyThePropellerHead) ISM8i Firmware v1.50 Update to be able to use the new DataPoints (FW Released in 2016) * As a side note the GLT °C boiler setpoint is defined and read as a 1°C resolution, but you can send the boiler setpoint commands with 0.1°C resolution
  • (RustyThePropellerHead) DHW minimum value reduced from 20°C to 0°C to allow for deactivation
  • (RustyThePropellerHead) Reorganisation of the hg0 to have its own area on the adapter configuration webpage.
  • (RustyThePropellerHead) Scalling DPT_FlowRate_m3/h corrected
  • (RustyThePropellerHead) Lookup "Programmwahl CWL" corrected

1.0.0 [2017.11.21]

  • (bluefox) resize logo

0.9.1 [2016.12.19]

  • (smiling_Jack) Add Bool option
  • (smiling_Jack) Add Bar option
  • (smiling_Jack) Bugfix Type 5.001 Scaling

0.1.0 [2015.12.01]

  • (smiling_Jack) Add writing to ism8

0.0.9 [2015.11.06]

  • (smiling_Jack) Bugfix
  • (smiling_Jack) Add test output

0.0.8 [2015.11.02]

  • (smiling_Jack) Bugfix io-package

0.0.7 [2015.11.02]

  • (smiling_Jack) new object management
  • (smiling_Jack) Bugfixes

0.0.6 [2015.10.20]

  • (smiling_Jack) Bugfix parsing

0.0.5 [2015.10.16]

  • (smiling_Jack) Add support for multiple data
  • (smiling_Jack) Add debug output
  • (smiling_Jack) Bugfixes

0.0.4 [2015.10.15]

  • (smiling_Jack) Bugfix on parse error
  • (smiling_Jack) Add DPT_HVACContrMode
  • (smiling_Jack) Add DPT_HVACMode

0.0.3 [2015.10.14]

  • (smiling_Jack) add CWL
  • (smiling_Jack) remove ISM8 ip

0.0.2 [2015.10.12]

  • (smiling_Jack) add BWL-1-S
  • (smiling_Jack) update readme

0.0.1 [2015.10.08]

  • (smiling_Jack) first release

License

The MIT License (MIT)

Copyright (c) 2015-2019 smiling_Jack

Permission is hereby granted, free of charge, to any person obtaining a copy of this software and associated documentation files (the "Software"), to deal in the Software without restriction, including without limitation the rights to use, copy, modify, merge, publish, distribute, sublicense, and/or sell copies of the Software, and to permit persons to whom the Software is furnished to do so, subject to the following conditions:

The above copyright notice and this permission notice shall be included in all copies or substantial portions of the Software.

THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.

About

Updates for ISM8i Firmware v1.50

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published

Languages

  • JavaScript 81.0%
  • HTML 19.0%