- baseScore: NULL
- baseSeverity: NULL
- More info about CVE-2024-22216 on NVD
In default installations of Microchip maxView Storage Manager (for Adaptec Smart Storage Controllers) where Redfish server is configured for remote system management, unauthorized access can occur, with data modification and information disclosure. This affects 3.00.23484 through 4.14.00.26064 (except for the patched versions 3.07.23980 and 4.07.00.25339).
- baseScore: NULL
- baseSeverity: NULL
- More info about CVE-2024-20365 on NVD
A vulnerability in the Redfish API of Cisco UCS B-Series, Cisco UCS Managed C-Series, and Cisco UCS X-Series Servers could allow an authenticated, remote attacker with administrative privileges to perform command injection attacks on an affected system and elevate privileges to root.
This vulnerability is due to insufficient input validation. An attacker with administrative privileges could exploit this vulnerability by sending crafted commands through the Redfish API on an affected device. A successful exploit could allow the attacker to elevate privileges to root.
- baseScore: NULL
- baseSeverity: NULL
- More info about CVE-2023-51438 on NVD
A vulnerability has been identified in SIMATIC IPC1047E (All versions with maxView Storage Manager < V4.14.00.26068 on Windows), SIMATIC IPC647E (All versions with maxView Storage Manager < V4.14.00.26068 on Windows), SIMATIC IPC847E (All versions with maxView Storage Manager < V4.14.00.26068 on Windows). In default installations of maxView Storage Manager where Redfish® server is configured for remote system management, a vulnerability has been identified that can provide unauthorized access.
- baseScore: NULL
- baseSeverity: NULL
- More info about CVE-2023-34330 on NVD
AMI SPx contains a vulnerability in the BMC where a user may inject code which could be executed via a Dynamic Redfish Extension interface. A successful exploit of this vulnerability may lead to a loss of confidentiality, integrity, and availability.
- baseScore: NULL
- baseSeverity: NULL
- More info about CVE-2023-25192 on NVD
AMI MegaRAC SPX devices allow User Enumeration through Redfish. The fixed versions are SPx12-update-7.00 and SPx13-update-5.00.
- baseScore: NULL
- baseSeverity: NULL
- More info about CVE-2023-25191 on NVD
AMI MegaRAC SPX devices allow Password Disclosure through Redfish. The fixed versions are SPx_12-update-7.00 and SPx_13-update-5.00.
- baseScore: NULL
- baseSeverity: NULL
- More info about CVE-2022-40258 on NVD
AMI Megarac Weak password hashes for Redfish & API
- baseScore: NULL
- baseSeverity: NULL
- More info about CVE-2022-3287 on NVD
When creating an OPERATOR user account on the BMC, the redfish plugin saved the auto-generated password to /etc/fwupd/redfish.conf without proper restriction, allowing any user on the system to read the same configuration file.
- baseScore: NULL
- baseSeverity: NULL
- More info about CVE-2019-1885 on NVD
A vulnerability in the Redfish protocol of Cisco Integrated Management Controller (IMC) could allow an authenticated, remote attacker to inject and execute arbitrary commands with root privileges on an affected device. The vulnerability is due to insufficient validation of user-supplied input by the affected software. An attacker could exploit this vulnerability by sending crafted authenticated commands to the web-based management interface of the affected software. A successful exploit could allow the attacker to inject and execute arbitrary commands on an affected device with root privileges.
- baseScore: 3.8
- baseSeverity: LOW
- More info about CVE-2018-15774 on NVD
Dell EMC iDRAC7/iDRAC8 versions prior to 2.61.60.60 and iDRAC9 versions prior to 3.20.21.20, 3.21.24.22, 3.21.26.22, and 3.23.23.23 contain a privilege escalation vulnerability. An authenticated malicious iDRAC user with operator privileges could potentially exploit a permissions check flaw in the Redfish interface to gain administrator access.
LastUpdate: Tue Oct 8 20:14:11 2024