Edit the section "Recovering a monitor's broken monmap" in
doc/rados/troubleshooting/troubleshooting-mon.rst.

Co-authored-by: Anthony D'Atri <[email protected]>
Signed-off-by: Zac Dover <[email protected]>
  • Loading branch information
zdover23 and anthonyeleven committed Nov 21, 2023
1 parent b0b050d commit 6ccb9f3
Showing 1 changed file with 58 additions and 51 deletions.
109 changes: 58 additions & 51 deletions doc/rados/troubleshooting/troubleshooting-mon.rst
Original file line number Diff line number Diff line change
Expand Up @@ -260,14 +260,15 @@ detail`` returns a message similar to the following::
Monitors at a wrong address. ``mon_status`` outputs the ``monmap`` that is
known to the monitor: determine whether the other Monitors' locations as
specified in the ``monmap`` match the locations of the Monitors in the
network. If they do not, see `Recovering a Monitor's Broken monmap`_.
If the locations of the Monitors as specified in the ``monmap`` match the
locations of the Monitors in the network, then the persistent
``probing`` state could be related to severe clock skews amongst the monitor
nodes. See `Clock Skews`_. If the information in `Clock Skews`_ does not
bring the Monitor out of the ``probing`` state, then prepare your system logs
and ask the Ceph community for help. See `Preparing your logs`_ for
information about the proper preparation of logs.
network. If they do not, see :ref:`Recovering a Monitor's Broken monmap
<rados_troubleshooting_troubleshooting_mon_recovering_broken_monmap>`. If
the locations of the Monitors as specified in the ``monmap`` match the
locations of the Monitors in the network, then the persistent ``probing``
state could be related to severe clock skews among the monitor nodes. See
`Clock Skews`_. If the information in `Clock Skews`_ does not bring the
Monitor out of the ``probing`` state, then prepare your system logs and ask
the Ceph community for help. See `Preparing your logs`_ for information about
the proper preparation of logs.


**What does it mean when a Monitor's state is ``electing``?**
Expand Down Expand Up @@ -324,13 +325,16 @@ detail`` returns a message similar to the following::
substantiate it. See `Preparing your logs`_ for information about the
proper preparation of logs.

.. _rados_troubleshooting_troubleshooting_mon_recovering_broken_monmap:

Recovering a Monitor's Broken ``monmap``
----------------------------------------
Recovering a Monitor's Broken "monmap"
--------------------------------------

This is how a ``monmap`` usually looks, depending on the number of
monitors::
A monmap can be retrieved by using a command of the form ``ceph tell mon.c
mon_status``, as described in :ref:`Understanding mon_status
<rados_troubleshoting_troubleshooting_mon_understanding_mon_status>`.

Here is an example of a ``monmap``::

epoch 3
fsid 5c4e9d53-e2e1-478a-8061-f543f8be4cf8
Expand All @@ -339,61 +343,64 @@ monitors::
0: 127.0.0.1:6789/0 mon.a
1: 127.0.0.1:6790/0 mon.b
2: 127.0.0.1:6795/0 mon.c
This may not be what you have however. For instance, in some versions of
early Cuttlefish there was a bug that could cause your ``monmap``
to be nullified. Completely filled with zeros. This means that not even
``monmaptool`` would be able to make sense of cold, hard, inscrutable zeros.
It's also possible to end up with a monitor with a severely outdated monmap,
notably if the node has been down for months while you fight with your vendor's
TAC. The subject ``ceph-mon`` daemon might be unable to find the surviving
monitors (e.g., say ``mon.c`` is down; you add a new monitor ``mon.d``,
then remove ``mon.a``, then add a new monitor ``mon.e`` and remove
``mon.b``; you will end up with a totally different monmap from the one
``mon.c`` knows).

In this situation you have two possible solutions:
This ``monmap`` is in working order, but your ``monmap`` might not be in
working order. The ``monmap`` in a given node might be outdated because the
node was down for a long time, during which the cluster's Monitors changed.

Scrap the monitor and redeploy
There are two ways to update a Monitor's outdated ``monmap``:

You should only take this route if you are positive that you won't
lose the information kept by that monitor; that you have other monitors
and that they are running just fine so that your new monitor is able
to synchronize from the remaining monitors. Keep in mind that destroying
a monitor, if there are no other copies of its contents, may lead to
loss of data.
A. **Scrap the monitor and redeploy.**

Inject a monmap into the monitor
Do this only if you are certain that you will not lose the information kept
by the Monitor that you scrap. Make sure that you have other Monitors in
good condition, so that the new Monitor will be able to synchronize with
the surviving Monitors. Remember that destroying a Monitor can lead to data
loss if there are no other copies of the Monitor's contents.

These are the basic steps:
B. **Inject a monmap into the monitor.**

Retrieve the ``monmap`` from the surviving monitors and inject it into the
monitor whose ``monmap`` is corrupted or lost.
It is possible to fix a Monitor that has an outdated ``monmap`` by
retrieving an up-to-date ``monmap`` from surviving Monitors in the cluster
and injecting it into the Monitor that has a corrupted or missing
``monmap``.

Implement this solution by carrying out the following procedure:
Implement this solution by carrying out the following procedure:

1. Is there a quorum of monitors? If so, retrieve the ``monmap`` from the
quorum::
#. Retrieve the ``monmap`` in one of the two following ways:

$ ceph mon getmap -o /tmp/monmap
a. **IF THERE IS A QUORUM OF MONITORS:**

Retrieve the ``monmap`` from the quorum:

2. If there is no quorum, then retrieve the ``monmap`` directly from another
monitor that has been stopped (in this example, the other monitor has
the ID ``ID-FOO``)::
.. prompt:: bash

$ ceph-mon -i ID-FOO --extract-monmap /tmp/monmap
ceph mon getmap -o /tmp/monmap

3. Stop the monitor you are going to inject the monmap into.
b. **IF THERE IS NO QUORUM OF MONITORS:**

Retrieve the ``monmap`` directly from a Monitor that has been stopped
:

4. Inject the monmap::
.. prompt:: bash

$ ceph-mon -i ID --inject-monmap /tmp/monmap
ceph-mon -i ID-FOO --extract-monmap /tmp/monmap

5. Start the monitor
In this example, the ID of the stopped Monitor is ``ID-FOO``.

.. warning:: Injecting ``monmaps`` can cause serious problems because doing
so will overwrite the latest existing ``monmap`` stored on the monitor. Be
careful!
#. Stop the Monitor into which the ``monmap`` will be injected.

#. Inject the monmap into the stopped Monitor:

.. prompt:: bash

ceph-mon -i ID --inject-monmap /tmp/monmap

#. Start the Monitor.

.. warning:: Injecting a ``monmap`` into a Monitor can cause serious
problems. Injecting a ``monmap`` overwrites the latest existing
``monmap`` stored on the monitor. Be careful!

Clock Skews
-----------