Expand Up @@ -12,35 +12,39 @@ If you have docker-compose installed, this is the fast way to get going:
docker-compose up
```


Assumptions made below:
1. The simulator server will use /dev/ttyS0 - can be adjusted in config/test.conf.
2. The example client will use /dev/ttyUSB0 - can also be adjust but is currently hardcoded in the slightly modified version of the example client written by Luc Jean and included with modbus-tk.
3. REST api served on port 5002.

1. The simulator server will use `/dev/ttyS0` - can be adjusted in `config/test.conf`
2. The example client will use `/dev/ttyUSB0` - can also be adjust but is currently hardcoded in the slightly modified version of the example client written by Luc Jean and included with modbus-tk.
3. REST api served on port `5002`.

Using a null modem emulator works as well.

To start the simulators REST server:
```

```sh
git clone https://github.com/emdem/ModbusSim.git
cd ModbusSim/src
sudo python3 server.py
```

Due to some funky threading related issues, currently, the simulator doesn't start until you visit the base url. Open your second terminal window and curl the root to setup the slave devices and start the modbus RTU server:
```

```sh
emre@nv-emre-lnx-1 ~ $ curl 0.0.0.0:5002
200 OKemre@nv-emre-lnx-1 ~ $
```

If you get a 200 OK, in the other terminal window you should see the following in the logs:
```

```sh
127.0.0.1 - - [13/Jul/2016 11:22:28] "GET / HTTP/1.1" 200 -
modbus_tk.simulator is running...
```

To interact with the API via browser, navigate to:
```

```sh
http://127.0.0.1:5002/api
```

Expand All @@ -52,23 +56,27 @@ http://127.0.0.1:5002/dump
```

Observe the values for the first slave. Saving the output with `curl -o` will allow you to restore all the registers with all the values for all slaves at that time. Then, you can load an sample simulator state from a json file like so:
```
#Assuming you are still in the ModbusSim/src directory

```sh
# Assuming you are still in the ModbusSim/src directory
curl -X POST -H "Content-Type:application/json" http://127.0.0.1:5002/dump -d@test/simulator_dump.json
```
Upon checking the values for the holding registers of the first slave, they should have changed to those included with the file. You can also verify by using a modbus RTU client/master to read the values over the wire.

To dump/load individual slave devices:
```

```sh
curl -X POST -H "Content-Type:application/json" http://127.0.0.1:5002/dump/slave/10 -d@test/slave_dump.json
```

To write to invidivual register:
```

```sh
curl -X POST -H "Content-Type:text/plain" -d "<INT_VALUE>" http://127.0.0.1:5002/slave/10/40001
```

To read from individual register:
```

```sh
curl http://127.0.0.1:5002/slave/10/40001
```