Skip to content

Home Assistant component for the myVAILLANT API, controls Vaillant devices such as aroTHERM heatpumps and ecoTEC boilers

License

Notifications You must be signed in to change notification settings

signalkraft/mypyllant-component

 
 

Repository files navigation

myPyllant Home Assistant Component

GitHub Release License GitHub Workflow Status

Home Assistant component that interfaces with the myVAILLANT API (and branded versions of it, such as the MiGo Link app from Saunier Duval & Bulex).

Warning

This integration is not affiliated with Vaillant, the developers take no responsibility for anything that happens to your devices because of this library.

myPyllant

Tested Setups

  • Vaillant aroTHERM plus heatpump + sensoCOMFORT VRC 720 + sensoNET VR 921
  • Vaillant ECOTEC PLUS boiler + VR940F + sensoCOMFORT
  • Vaillant ECOTEC PLUS boiler + VRT380f + sensoNET
  • Vaillant EcoCompact VSC206 4-5 boiler + Multimatic VRC700/6 + gateway VR920
  • Saunier Duval DUOMAX F30 90 + MISET Radio + MiLink V3
  • VR42 controllers are also supported
  • More are documented here

Features

Default Dashboard Screenshot

  • Supports climate & hot water controls, as well as sensor information
  • Control operating modes, target temperature, and presets such as holiday more or quick veto
  • Set the schedule for climate zones, water heaters, and circulation pumps with a custom service
  • Track sensor information of devices, such as temperature, humidity, operating mode, energy usage, or energy efficiency
  • See diagnostic information, such as the current heating curve, flow temperature, firmware versions, or water pressure
  • Custom services to set holiday mode or quick veto temperature overrides, and their duration

Installation

HACS

  1. Install HACS
  2. Search for the myVAILLANT integration in HACS and install it
  3. Restart Home Assistant
  4. Add myVaillant integration
  5. Sign in with the email & password you used in the myVAILLANT app (or MiGo app for Saunier Duval)

Manual

  1. Download the latest release
  2. Extract the custom_components folder to your Home Assistant's config folder, the resulting folder structure should be config/custom_components/mypyllant
  3. Restart Home Assistant
  4. Add myVaillant integration, or go to Settings > Integrations and add myVAILLANT
  5. Sign in with the email & password you used in the myVAILLANT app (or MiGo app for Saunier Duval & Bulex)

Options

Seconds between scans

Wait interval between updating (most) sensors. Don't set this too low, for example 10 leads to quota exceeded errors and a temporary ban.

The energy data and efficiency sensors have a fixed hourly interval.

Delay before refreshing data after updates

How long to wait between making a request (i.e. setting target temperature) and refreshing data. The Vaillant takes some time to return the updated values.

Default duration in hours for quick veto

When setting the temperature with the climate controls, the integration uses the "quick veto" feature of the myVAILLANT app.

With this option you can set for how long the temperature should stay set, before returning to the default value.

Default duration in days for away mode

When the away mode preset is activated, this duration is used to for the end date (default is 365 days).

Temperature controls overwrite time program instead of setting quick veto

When raising or lowering the desired temperature in the myVAILLANT app, it sets a quick veto mode for a limited time with that new temperature, if the zone is in time controlled mode. If you want to permanently change the desired temperature, you need to update the time schedule.

By default, this integration has the same behavior. But when enabling this option, the Home Assistant climate controls instead overwrite the temperatures set in the time schedule with the new value (unless quick veto is already active).

Country

The country you registered your myVAILLANT account in. The list of options is limited to known supported countries.

If a country is missing, please open an issue.

Brand

Brand of your HVAC equipment and app, pick Saunier Duval if you use the MiGo Link app.

Known Issues

Lack of Test Data for Different Systems

Your HVAC system might differ from the ones in Tested on above. If you don't see any entities, or get an error during setup, please check Debugging below and create an issue. With debugging enabled, there's a chance to find the culprit in the data returned by the myVAILLANT API and fix it.

Entities

You can expect these entities, although names will vary based on your home name (here "Home"), installed devices (in this example "aroTHERM plus" and "hydraulic station"), or the naming of your heating zones (in this case "Zone 1"):

Entity Unit Class Sample
Home Trouble Codes problem off
Home Online Status connectivity on
Home Firmware Update Required update off
Home Firmware Update Enabled on
Home EEBUS Enabled on
Home EEBUS Capable on
Home Circuit 0 Cooling Allowed on
Home Zone 1 (Circuit 0) Manual Cooling Active off
Home Zone 1 (Circuit 0) on
Home Zone 1 (Circuit 0) on
Home Domestic Hot Water 0 on
Circulating Water in Home Domestic Hot Water 0 off
Home Zone 1 (Circuit 0) Climate auto
Home Away Mode Start Date unknown
Home Away Mode End Date unknown
Home Manual Cooling Start Date unknown
Home Manual Cooling End Date unknown
Home Holiday Duration Remaining d 0
Home Manual Cooling Duration d 0
Home Zone 1 (Circuit 0) Quick Veto Duration h 2
Home Circuit 0 Heating Curve 1.2733452
Home Circuit 0 Heat Demand Limited by Outside Temperature °C 18.0
Home Circuit 0 Min Flow Temperature Setpoint °C 32.0
Vaillant API Request Count 51
Home Outdoor Temperature °C temperature 17.3
Home System Water Pressure bar pressure 1.5
Home Firmware Version 0357.40.35
Home Zone 1 (Circuit 0) Desired Temperature °C temperature 0.0
Home Zone 1 (Circuit 0) Desired Heating Temperature °C temperature 0.0
Home Zone 1 (Circuit 0) Desired Cooling Temperature °C temperature 25.0
Home Zone 1 (Circuit 0) Current Temperature °C temperature 21.5
Home Zone 1 (Circuit 0) Humidity % humidity 62.0
Home Zone 1 (Circuit 0) Heating Operating Mode Time Controlled
Home Zone 1 (Circuit 0) Heating State Idle
Home Zone 1 (Circuit 0) Current Special Function Quick Veto
Home Circuit 0 State STANDBY
Home Circuit 0 Current Flow Temperature °C temperature 41.0
Home Circuit 0 Heating Curve 1.27
Home Domestic Hot Water 0 Tank Temperature °C temperature 51.5
Home Domestic Hot Water 0 Setpoint °C temperature 52.0
Home Domestic Hot Water 0 Operation Mode Time Controlled
Home Domestic Hot Water 0 Current Special Function Regular
Home Heating Energy Efficiency 4.9
Home Device 0 aroTHERM plus Heating Energy Efficiency 4.9
Home Device 0 aroTHERM plus Consumed Electrical Energy Cooling Wh energy 0.0
Home Device 0 aroTHERM plus Consumed Electrical Energy Domestic Hot Water Wh energy 3000.0
Home Device 0 aroTHERM plus Consumed Electrical Energy Heating Wh energy 4000.0
Home Device 0 aroTHERM plus Earned Environment Energy Cooling Wh energy 0.0
Home Device 0 aroTHERM plus Earned Environment Energy Domestic Hot Water Wh energy 9000.0
Home Device 0 aroTHERM plus Earned Environment Energy Heating Wh energy 18000.0
Home Device 0 aroTHERM plus Heat Generated Heating Wh energy 22000.0
Home Device 0 aroTHERM plus Heat Generated Domestic Hot Water Wh energy 12000.0
Home Device 0 aroTHERM plus Heat Generated Cooling Wh energy 0.0
Home Device 1 Hydraulic Station Heating Energy Efficiency unknown
Home Device 1 Hydraulic Station Consumed Electrical Energy Domestic Hot Water Wh energy 0.0
Home Device 1 Hydraulic Station Consumed Electrical Energy Heating Wh energy 0.0
Home Away Mode off
Home EEBUS on
Home Manual Cooling off
Home Domestic Hot Water 0 Boost off
Home Zone 1 (Circuit 0) Ventilation Boost off
Home Domestic Hot Water 0 Time Controlled

Services

There are custom services for almost every functionality of the myVAILLANT app:

Name Description Target Fields
Set quick veto Sets quick veto temperature with optional duration climate Temperature, Duration
Set manual mode setpoint Sets temperature for manual mode climate Temperature, Type
Cancel quick veto Cancels quick veto temperature and returns to normal schedule / manual setpoint climate
Set holiday Set holiday / away mode with start / end or duration climate Start Date, End Date, Duration
Cancel Holiday Cancel holiday / away mode climate
Set Zone Time Program Updates the time program for a zone climate Type, Time Program
Set Water Heater Time Program Updates the time program for a water heater water_heater Time Program
Set Water Heater Circulation Time Program Updates the time program for the circulation pump of a water heater water_heater Time Program
Export Data Exports data from the mypyllant library Data, Data Resolution, Start Date, End Date
Generate Test Data Generates test data for the mypyllant library and returns it as YAML
Export Yearly Energy Reports Exports energy reports in CSV format per year Year

Additionally, there are home assistant's built in services for climate controls, water heaters, and switches.

Search for "myvaillant" in Developer Tools > Services in your Home Assistant instance to get the full list plus an interactive UI.

Open your Home Assistant instance and show your service developer tools with a specific service selected.

Contributing

See the docs on contributing.

Debugging

When debugging or reporting issues, turn on debug logging by adding this to your configuration.yaml and restarting Home Assistant:

logger:
  default: warning
  logs:
    custom_components.mypyllant: debug
    myPyllant: debug

Contributing to the underlying mypyllant library

See this section on the contributing docs.